Learn. Consult. Act. · Working demonstration

Follow the evidence behind a yield shift.

Connect the lots. Understand the baseline. Reason about competing explanations. Bring the next step to an engineer for approval.

Synthetic data only. All lots, equipment, timestamps, parameters, and outcomes are fictional. This is a reproducible technical demonstration, not customer results or a validated production decision. It runs locally without internet, credentials, or an LLM after dependencies are installed.
01 · Connect & understand

One fixture. A repeatable investigation.

Each lot is one subgroup of inspected units, classified once as accepted or rejected. Filter the same chronological records by lot, equipment, temperature, and operator shift. Filters apply together; the reference baseline stays fixed.

Reset all filters
Fixture provenance & reproducibility

Dataset synthetic-yield-v1, schema 1. Checked-in source: site_pages/data/synthetic_yield_v1.json. Calculations: site_pages/demo.py. Recipe, assumptions, and offline instructions: site_pages/data/README.md.

SHA-256 of the loaded fixture: fac0e1bd061ba236752deeb0e42c20b7b4722e8eef29361ab4940bef45527bb4. Repeating a selection produces the same values; no generated AI text or external retrieval is involved.

02 · Detect

A process signal to investigate.

48 selected lots. Predefined baseline: SYN-001–SYN-024; monitoring: SYN-025–SYN-048. Full fixture spans 2026-01-01T06:00:00+00:00 to 2026-01-12T22:00:00+00:00 (UTC).

Fixed reference: 168 rejected / 5280 inspected units in 24 baseline lots = 3.18% defects (96.82% yield). The baseline was specified before looking at monitoring data; filters never refit it.

Intervals below are conditional binomial model references. Mixed populations and dependence between units can invalidate their nominal coverage; they are not validated production uncertainty. See assumptions and limits before interpreting them.

Selected baseline

3.18% defects · 96.82% yield

168 rejected / 5280 inspected units · 24 lots
Approx. 95% Wilson defect interval (binomial model): 2.74% to 3.69%

Selected monitoring

7.50% defects · 92.50% yield

396 rejected / 5280 inspected units · 24 lots
Approx. 95% Wilson defect interval (binomial model): 6.82% to 8.24%

Defect-rate change

4.32 percentage points
Conditional approx. 95% interval: 2.96 to 5.67 percentage points.

Monitoring minus baseline. Positive means lower yield.

12 / 24 selected monitoring lots outside limits. First selected alert: SYN-026 (Press-B, Day, 190 °C). This locates a signal, not the exact onset or cause. Selected baseline alerts: 0 / 24 lots.

Lot defect p-chart against the fixed baseline Defect percentage by original lot sequence. Solid teal center, dashed navy size-dependent limits. Orange squares mark outside-limit lots; teal circles mark other lots. All exact values and limit status are in the lot table below. 0.0%5.0%10.0%15.0% Defects (%) · higher is worse Baseline lots 1–24Monitoring lots 25–48 148
Solid teal: baseline center. Dashed navy: three-sigma limits, varying with lot size. Orange square: outside limits. Teal circle: within limits. Horizontal axis: original lot sequence. On small screens, scroll the chart; the complete values follow in the table.
Inspect the selected lots & exact chart values

Every row is server-rendered.

Selected synthetic lots; defect p-chart limits from the full baseline
Lot / UTC / periodEquipment / shift / temperatureRejected / inspectedDefects / yieldLower / upper limitsStatus
SYN-001

Baseline
Press-A
Day · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-002

Baseline
Press-B
Day · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-003

Baseline
Press-A
Night · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-004

Baseline
Press-B
Night · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-005

Baseline
Press-A
Day · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-006

Baseline
Press-B
Day · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-007

Baseline
Press-A
Night · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-008

Baseline
Press-B
Night · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-009

Baseline
Press-A
Day · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-010

Baseline
Press-B
Day · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-011

Baseline
Press-A
Night · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-012

Baseline
Press-B
Night · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-013

Baseline
Press-A
Day · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-014

Baseline
Press-B
Day · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-015

Baseline
Press-A
Night · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-016

Baseline
Press-B
Night · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-017

Baseline
Press-A
Day · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-018

Baseline
Press-B
Day · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-019

Baseline
Press-A
Night · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-020

Baseline
Press-B
Night · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-021

Baseline
Press-A
Day · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-022

Baseline
Press-B
Day · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-023

Baseline
Press-A
Night · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-024

Baseline
Press-B
Night · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-025

Monitoring
Press-A
Day · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-026

Monitoring
Press-B
Day · 190 °C
26 / 22011.82% / 88.18%0.00% / 6.73%Outside limits
SYN-027

Monitoring
Press-A
Night · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-028

Monitoring
Press-B
Night · 190 °C
24 / 20012.00% / 88.00%0.00% / 6.91%Outside limits
SYN-029

Monitoring
Press-A
Day · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-030

Monitoring
Press-B
Day · 190 °C
28 / 24011.67% / 88.33%0.00% / 6.58%Outside limits
SYN-031

Monitoring
Press-A
Night · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-032

Monitoring
Press-B
Night · 190 °C
26 / 22011.82% / 88.18%0.00% / 6.73%Outside limits
SYN-033

Monitoring
Press-A
Day · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-034

Monitoring
Press-B
Day · 190 °C
24 / 20012.00% / 88.00%0.00% / 6.91%Outside limits
SYN-035

Monitoring
Press-A
Night · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-036

Monitoring
Press-B
Night · 190 °C
28 / 24011.67% / 88.33%0.00% / 6.58%Outside limits
SYN-037

Monitoring
Press-A
Day · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-038

Monitoring
Press-B
Day · 190 °C
26 / 22011.82% / 88.18%0.00% / 6.73%Outside limits
SYN-039

Monitoring
Press-A
Night · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-040

Monitoring
Press-B
Night · 190 °C
24 / 20012.00% / 88.00%0.00% / 6.91%Outside limits
SYN-041

Monitoring
Press-A
Day · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-042

Monitoring
Press-B
Day · 190 °C
28 / 24011.67% / 88.33%0.00% / 6.58%Outside limits
SYN-043

Monitoring
Press-A
Night · 180 °C
6 / 2003.00% / 97.00%0.00% / 6.91%Within limits
SYN-044

Monitoring
Press-B
Night · 190 °C
26 / 22011.82% / 88.18%0.00% / 6.73%Outside limits
SYN-045

Monitoring
Press-A
Day · 180 °C
8 / 2403.33% / 96.67%0.00% / 6.58%Within limits
SYN-046

Monitoring
Press-B
Day · 190 °C
24 / 20012.00% / 88.00%0.00% / 6.91%Outside limits
SYN-047

Monitoring
Press-A
Night · 180 °C
7 / 2203.18% / 96.82%0.00% / 6.73%Within limits
SYN-048

Monitoring
Press-B
Night · 190 °C
28 / 24011.67% / 88.33%0.00% / 6.58%Outside limits
How the p-chart works

Plot rejected / inspected per lot. Center p̄ = total baseline rejects / total baseline inspected. Limits for each lot size n are max(0, p̄ − 3√(p̄(1−p̄)/n)) and min(1, p̄ + 3√(p̄(1−p̄)/n)). Outside-limit lots are flagged; no additional run rules or fitted change-point model are used. The dashed boundary marks the predefined monitoring window, not an estimated onset.

Each lot is a rational subgroup with one equipment/temperature/shift setting. The deliberately balanced baseline supports a pooled reference in this fixture. A real investigation must first verify stable, comparable baseline strata and the inspection system. Normal-approximation limits are withheld if expected rejects or accepts are below five. Control limits are neither specification limits nor confidence intervals.

The line shows limits for every original lot size; only selected observations are drawn. The ordinal lot axis stays fixed when filtered. This binary outcome calls for a p-chart, not continuous-measurement Cpk or X-bar charts. Method reference: NIST proportions control charts (optional reading; not required to run).

03 · Reason

Compare associations before choosing a hypothesis.

These strata use your selected lots and the same two time windows. Every rate is weighted by inspected units. Empty cells are missing evidence. Explore equipment and shift before interpreting temperature.

Equipment

Press-A

Baseline

3.18% defects · 96.82% yield

84 rejected / 2640 inspected units · 12 lots
Approx. 95% Wilson defect interval (binomial model): 2.58% to 3.92%

Monitoring

3.18% defects · 96.82% yield

84 rejected / 2640 inspected units · 12 lots
Approx. 95% Wilson defect interval (binomial model): 2.58% to 3.92%

Change in defect rate:

0.00 percentage points
Conditional approx. 95% interval: -1.54 to 1.54 percentage points.

Press-B

Baseline

3.18% defects · 96.82% yield

84 rejected / 2640 inspected units · 12 lots
Approx. 95% Wilson defect interval (binomial model): 2.58% to 3.92%

Monitoring

11.82% defects · 88.18% yield

312 rejected / 2640 inspected units · 12 lots
Approx. 95% Wilson defect interval (binomial model): 10.64% to 13.11%

Change in defect rate:

8.64 percentage points
Conditional approx. 95% interval: 6.44 to 10.80 percentage points.

Temperature (°C)

180 °C

Baseline

3.18% defects · 96.82% yield

168 rejected / 5280 inspected units · 24 lots
Approx. 95% Wilson defect interval (binomial model): 2.74% to 3.69%

Monitoring

3.18% defects · 96.82% yield

84 rejected / 2640 inspected units · 12 lots
Approx. 95% Wilson defect interval (binomial model): 2.58% to 3.92%

Change in defect rate:

0.00 percentage points
Conditional approx. 95% interval: -1.27 to 1.36 percentage points.

190 °C

Baseline

Unavailable: 0 lots / 0 inspected units. No rate or interval.

Monitoring

11.82% defects · 88.18% yield

312 rejected / 2640 inspected units · 12 lots
Approx. 95% Wilson defect interval (binomial model): 10.64% to 13.11%

Change in defect rate:

Unavailable: both periods need inspected units. No before/after effect can be estimated.

Shift

Day

Baseline

3.18% defects · 96.82% yield

84 rejected / 2640 inspected units · 12 lots
Approx. 95% Wilson defect interval (binomial model): 2.58% to 3.92%

Monitoring

7.50% defects · 92.50% yield

198 rejected / 2640 inspected units · 12 lots
Approx. 95% Wilson defect interval (binomial model): 6.56% to 8.57%

Change in defect rate:

4.32 percentage points
Conditional approx. 95% interval: 2.39 to 6.23 percentage points.

Night

Baseline

3.18% defects · 96.82% yield

84 rejected / 2640 inspected units · 12 lots
Approx. 95% Wilson defect interval (binomial model): 2.58% to 3.92%

Monitoring

7.50% defects · 92.50% yield

198 rejected / 2640 inspected units · 12 lots
Approx. 95% Wilson defect interval (binomial model): 6.56% to 8.57%

Change in defect rate:

4.32 percentage points
Conditional approx. 95% interval: 2.39 to 6.23 percentage points.

04 · Explain the limits

Association is not causation.

Confounding is built in

The fixture recipe changes temperature only on Press-B in the monitoring window. Equipment, temperature, and period overlap: there are no high-temperature baseline lots and no high-temperature Press-A lots. Temperature and the Press-B period change cannot be separated with these records.

Day and Night both appear across equipment and periods. Comparing them helps expose mix effects; it cannot rule out unmeasured material, maintenance, calibration, or operator differences in real data. The planted recipe is teaching context, not an inferred causal mechanism.

Intervals are conditional

Rate intervals are approximate 95% Wilson score intervals for defects. Change intervals subtract two 97.5% Wilson intervals for conservative, approximate 95% joint coverage for that pair. They assume independent Bernoulli units with a common rate within each reported population.

Mixed strata, within-lot correlation, serial dependence, overdispersion, and estimated baseline uncertainty can make these intervals or chart limits too narrow. The pooled monitoring mixture does not have a single common rate. These are conditional model references, not dependable production or causal uncertainty estimates. The deterministic fixture is not a random production sample.

Exploration has a cost

Filtering, many strata, and repeated chart checks increase false-alert opportunities. The period-pair interval correction does not adjust for these multiple comparisons. These are exploratory signals, not confirmatory significance tests or proof of equivalence.

Before real use, inspect baseline strata, measurement quality, dependence, and lot replication. Predefine a confirmatory plan; consider a model for clustered or overdispersed data with an engineer/statistician. NIST Wilson interval reference (optional reading).

05 · Act with approval

A reviewable next step, owned by a person.

This demonstration recommends investigation only. It cannot change equipment, release product, or send messages.

  1. Quality Engineering review: reconcile inspection definitions, lot traceability, and measurement calibration; assess affected product under approved procedures. A chart alert alone does not determine product disposition.
  2. Process Engineering review: examine the equipment and parameter strata, maintenance records, material lots, and both shifts. Confirm the baseline is comparable before treating the alert as operational evidence.
  3. Named owner approval before any trial or process change: propose a safe, replicated, randomized or blocked follow-up that separates equipment, temperature, and time. Agree limits, sample size, response criteria, and rollback with Quality and Process Engineering first.
  4. Human sign-off on the conclusion: validate on new lots, report uncertainty and contradictory evidence, and record the decision. Do not claim a yield gain from this synthetic association.

Explore the reference architecture behind this workflow or compare the separate illustrative team walkthrough. Its fictional exhibits use different data and are not sources for these calculations.

Bring us your hardest question about your operation.

Use a 90-minute process review to explore the evidence, data access, and validation a private operational intelligence pilot would need.

Explore Your Operational Intelligence Opportunity